В Bazar.BG от 01 ноември 2024г.
Последно активен днес в 01:24 ч.
Voltronic Axpert MAX II 10000-48 Inverter 10kw single-phase 48Volt solar photovoltaic for off-grid stand-alone systems
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485, CAN-BUS or RS232)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
• High power selectable charging current
• Selectable input voltage range for home appliances and personal computers
• Communication with BMS battery Pylontech US2000 / US3000, Solarpower24 2.4kw / 4.8kw
• Compatible with mains or generator input
• Built-in dustproof kit
• Optional DC output for DC fan, LED bulb, router and so on.
• Parallel operation with 6 units
MODEL
10KW
Input voltage waveform
Sinusoidal (AC mains or generator)
Rated input voltage
230Vac
Low voltage loss
170Vac ± 7V (UPS)
90Vac ± 7V (equipment)
Low Return Voltage Drop
180Vac ± 7V (UPS);
100Vac ± 7V (Equipment)
High Voltage Drop
280Vac ± 7V
High Return Voltage Drop
270Vac ± 7V
Max. AC input voltage
300Vac
Current Max. AC input
60A
Rated input frequency
50Hz / 60Hz (Auto Detect)
Low Frequency Drop
40 ± 1Hz
Low Return Voltage Drop
42 ± 1Hz
High Frequency Drop
65 ± 1Hz
High Return Voltage Drop
63 ± 1Hz
Short circuit protection at the output
Line Mode: RCD (70A)
Battery mode: Electronic Circuits
Efficiency (Line Mode)
>95% (Rated load R, battery fully charged)
Transfer duration
10ms typical (UPS);
20ms typical (equipment);
Output power reduction:
If the AC input voltage drops below 170V, the output power will be reduced.
MODEL
10KW
Rated output power
10000W
Output voltage waveform
Pure sine wave
Output voltage regulation
230Vac ± 5%
Output frequency
60Hz or 50Hz
Peak efficiency
93%
Overload protection
100ms @ ≥205% load; 5s @ ≥150% load; 10s @ 110 %~150% load
Overload capacity
2 * Rated power for 5 seconds
Low DC alarm voltage
46.0Vdc
42.8Vdc
40.4Vdc
@ load< 20%
@ 20% ≤ load< 50%
@ load ≥ 50%
Low DC Alarm Return Voltage
48.0Vdc
44.8Vdc
42.4Vdc
@ load< 20%
@ 20% ≤ load< 50%
@ load ≥ 50%
Low DC cutoff voltage
44.0Vdc
40.8Vdc
38.4Vdc
@ load< 20%
@ 20% ≤ load< 50%
@ load ≥ 50%
High recovery DC voltage
61Vdc
High DC cutoff voltage
63Vdc
DC voltage accuracy
+/- 0.3V @ no load
THDV
<5% for linear load,< 10% for non-linear load @ rated voltage
DC offset
≦ 100mV
Consumption without load
<75W
AC Grid Load Mode
MODEL
10KW
Charging current (UPS)
@ Nominal input voltage
Bulk Charge Voltage
Lead-acid battery
58.4Vdc
AGM / Gel battery
56.4Vdc
Charging float voltage
54Vdc
Overload protection
63Vdc
Charging algorithm
3 step
Charge curve
Solar entrance
MODEL
10KW
Nominal power
10000W
Max. PV array open circuit voltage
500Vdc
PV array MPPT voltage range
90Vdc ~ 450Vdc
Max. Input current
18A x 2
Starting voltage
80V +/- 5Vdc
Power limitation
Table 4 General Specifications
MODEL
10KW
Safety certification
THERE IS
Operating temperature range
– 10 ° C + 50 ° C
Storage temperature
-15 ° C ~ 60 ° C
Humidity
5 – 95% relative humidity (non-condensing)
Dimensions (P * W * H), mm
158.4x 503.6 x 530.8
Net weight, kg
20
Table 5 Parallel Specifications
Nr. max. in parallel
6
Circulation current under no-load conditions
Max. 2A
Power imbalance ratio
<5% @ 100% load
Parallel communication
CAN
Transfer time in parallel mode
Max.50ms